Browsing the Boost mode information

To browse the basic information of the Boost mode:

  1. Press the Change mode button until the icon of the Boost mode appears on the display:
  2. Please wait until the main view of the Boost mode opens:

    The main view shows a summary of the mode information.

  3. Select Boost information:

    The first mode information screen opens:

    This screen shows the following information:

    • Supply air — Indicates the actual temperature of the air flowing into the apartment and the supply air temperature setting (in parentheses) if the supply air is warmer than the value set.

    • Outdoor airIndicates the outdoor temperature.

    • Fan speedIndicates the fan speed. If the automatic fan speed boost is active, the set value is shown in brackets, followed by the real fan speed.

    • Cell status — The ventilation unit has the following HR cell modes:

      • Heat recoveryThe HR cell heats the air flowing in from outdoors with extract air.
      • Cold recoveryThe HR cell cools the air flowing in from outdoors with extract air when the temperature of the air that is extracted from the apartment is two degrees lower than the outdoor temperature.
      • BypassThe inflowing air bypasses the HR cell.
      • HR cell defrost in progressThe HR cell is being defrosted.
  4. Select Right arrow. The second mode information screen opens:

    This screen shows the following information:

    • HumidityIndicates the highest relative humidity value measured by the sensors.
    • Carbon dioxideIndicates the highest carbon dioxide value measured by the sensors.
    • Replace filters — Indicates the next recommended filter replacement date.
    • Time in operation — Indicates for how long the unit has been running.