Sound values

Table 1. Sound power level in the supply air duct
Sound power level in the supply air duct by octave band LW´ dB
Adjustment position (%) 10 20 30 40 50 60 70 100
Air flow (dm3/s) 1020323747576265
Medium frequency of the octave band Hz 63 6067687273797978
125 5665646668707273
250 5158677074787676
500 4149555963667070
1000 3947525558626566
2000 3041485256596262
4000 1928364246515455
8000 2122283542485253
LW, dB 6170727577828281
LWA, dB(A) 4655616468727275
Table 2. Sound power level in the extract air duct
Sound power level in the extract air duct by octave band LW´ dB
Adjustment position (%) 10 20 30 40 50 60 70 100
Air flow (dm3/s) 1722364251606667
Medium frequency of the octave band Hz 63 5458596366787073
125 4856545658626364
250 4350615961636564
500 3037434649536060
1000 2735394346505253
2000 1523293337404243
4000 1717182125293132
8000 2121212122232526
LW, dB 5561646568787274
LWA, dB(A) 3845535254586161
Table 3. Sound pressure level in the room
Sound pressure level coming through the envelope of the unit in the room in which it is installed (10m² sound absorption)
Adjustment position (%) 10 20 30 40 50 60 70 100
Air flow dm3/s (supply/extract) 15/1733/3932/3638/4247/5157/6062/6765/67
LpA, dB (A) 2733404346505252

You can calculate the sound values for each operating point with the Vallox MySelecta control panel.