Table 1. Technical properties MyVallox 51 CFi
Product titles

MyVallox 51 CFi R

MyVallox 51 CFi L

Type code3830
Air volumes
  • Supply air — 44 dm3/s, 100 Pa
  • Extract air — 45 dm3/s, 100 Pa
Electric connection230 V, 50 Hz, 4.24 A plug
Enclosure classIP 34
Post-heatingElectrical resistor, 900 W
Pre-heating-
Additional heating-
Fans
  • Extract air — 0.035 kW 0.35 A EC
  • Supply air — 0.035 kW 0.35 A EC
Specific energy consumption (SEC)
  • Cold climate — A+
  • Temperate climate — A+
Efficiency*
  • Annual efficiency — 81%
  • Supply air efficiency — 89%
  • Specific fan power SFP — 1.04 kW/m3/h (32 dm3/s)
Filters
  • Supply air — ISO Coarse > 75% + ISO ePM1 ≥ 50%
  • Extract air — ISO Coarse > 75%
HR cell bypassAutomatic
Dimensions (width x height x depth)598 x 668 x 349 mm
Weight45 kg
*Working point defined in the Ecodesign Directive (2009/125/EC), Southern Finland, Helsinki-Vantaa TRY year 2020.
Table 2. Technical properties MyVallox CFi, enthalpy
Product titles

MyVallox 51 CFi R enthalpy

MyVallox 51 CFi L enthalpy

Type code3831
Air volumes
  • Supply air — 44 dm3/s, 100 Pa
  • Extract air — 45 dm3/s, 100 Pa
Electric connection230 V, 50 Hz, 4.24 A plug
Enclosure protection classIP 34
Post-heatingElectrical resistor, 900 W
Pre-heating-
Additional heating-
Fans
  • Extract air — 0.035 kW 0.35 A EC
  • Supply air — 0.035 kW 0.35 A EC
Specific energy consumption (SEC)
  • Cold climate — A+
  • Temperate climate — A+
Efficiency*
  • Supply air efficiency — 88%
  • Specific fan power SFP — 1.01 kW/m3/h (32 dm3/s)
Filters
  • Supply air — ISO Coarse > 75% + ISO ePM1 ≥ 50%
  • Extract air — ISO Coarse > 75%
HR cell bypassAutomatic
Dimensions (width x height x depth)598 x 668 x 349 mm
Weight45 kg