Dimensions and duct outlets

Figure 1. Dimensions

There are two condensing water discharge outlets at the bottom. The condensing water outlet or siphon is connected to a free, not plugged, discharge outlet.

A — The condensing water outlet/siphon is connected here in case of a right-handed unit.

B — The condensing water outlet /siphon is connected here in case of a left-handed unit.

Figure 2. Duct outlets, L model and R model

Duct outlets

Inner diameter of the female collar ∅ 125 mm.

  1. Supply air from unit to apartment
  2. Extract air from apartment to unit
  3. Exhaust air from unit to outdoors
  4. Outdoor air to unit

HR cell support locations

Figure 3. HR cell support locations, L model and R model
  1. Supply air
  2. Extract air
  3. Coarse filter
  4. Fine filter
  5. Upper support of the cell
  6. Lower support for the HR cell