Technical data

Table 1. Technical data Vallox 245 MV
ObjectVallox 245 MV
Product titles

Vallox 245 MV R

Vallox 245 MV L

Type codeA3732
Electrical connection230 V, 50 Hz, 14.5 A power plug
Enclosure protection classIP34
Fans
  • Supply air — 0.170 kW 1.25 A EC
  • Extract air — 0.170 kW 1.25 A EC
Air volumes
  • Supply air — 247 dm3/s, 100 Pa
  • Extract air — 271 dm3/s, 100 Pa
Efficiencies*
  • Annual efficiency — 82%
  • Supply air efficiency — 85%
  • Specific Fan Power (SFP) — 0.68 kW (181 dm3/s)
Heat recovery bypassAutomatic
Post-heatingElectrical resistor, 1500 W
Pre-heating-
Additional heatingElectrical resistor, 1500 W
Filters
  • Supply air — ISO Coarse > 75% + ISO ePM1 ≥ 50%
  • Extract air — ISO Coarse > 75%
Specific energy consumption (SEC)
  • In a cold climate — A+
  • In a temperate climate — A+
Dimensions1038 x 1241 x 773 mm
Weight181 kg
*Working point defined in the Ecodesign Directive (2009/125/EC), Southern Finland, Helsinki-Vantaa TRY year 2020.
Table 2. Technical data Vallox 245 MV VKL
ObjectVallox 245 MV VKL
Product titles

Vallox 245 MV VKL R

Vallox 245 MV VKL L

Type codeA3732
Electrical connection230 V, 50 Hz, 14.5 A power plug
Enclosure protection classIP34
Fans
  • Supply air — 0.170 kW 1.25 A EC
  • Extract air — 0.170 kW 1.25 A EC
Air volumes
  • Supply air — 229 dm3/s, 100 Pa
  • Extract air — 269 dm3/s, 100 Pa
Efficiencies*
  • Annual efficiency — 82%
  • Supply air efficiency — 85%
  • Specific Fan Power (SFP) — 0.70 kW (181 dm3/s)
Heat recovery bypassAutomatic
Post-heatingLiquid circulating radiator
Pre-heating-
Additional heatingElectrical resistor, 3000 W
Filters
  • Supply air — ISO Coarse > 75% + ISO ePM1 ≥ 50%
  • Extract air — ISO Coarse > 75%
Specific energy consumption (SEC)
  • In a cold climate — A+
  • In a temperate climate — A+
Dimensions1038 x 1241 x 773 mm
Weight187 kg
*Working point defined in the Ecodesign Directive (2009/125/EC), Southern Finland, Helsinki-Vantaa TRY year 2020.