Vallox 101 MV

Table 1. Technical data
Object Vallox 101 MV
Product titles

Vallox 101 MV R

Vallox 101 MV L

Type codes B3741
Product numbers

4102189 (R model)

4102197 (L model)

HVAC codes

7912119 (R model)

7912120 (L model)

Electrical connection 230 V, 50 Hz, 8.3 A (power plug)
Enclosure protection class IP 34
Fans
  • Extract air — 0.115 kW 0.9 A EC
  • Supply air — 0.115 kW 0.9 A EC
Air volumes
  • Supply air — 90 dm3/s, 100 Pa
  • Extract air — 98 dm3/s, 100 Pa
Efficiencies
  • Annual efficiency: 70% A
  • Supply air efficiency: 82%
  • Specific Fan Power SFP: 1.0 kW (38 dm3/s) A
Heat recovery Cross-counter flow cell, η>80%
Heat recovery bypass Automatic
Post-heating Electrical resistor, 1500 W
Pre-heating -
Additional heating -
Filters
  • Supply air — ISO Coarse > 75% + ISO ePM1
  • Extract air — ISO Coarse > 75%
Specific energy consumption (SEC)
  • In a cold climate — A+
  • In a temperate climate — A
Dimensions without the siphon (width x height x depth) 598 x 449 x 596 mm
Weight 58 kg
Ventilation efficiency control
  • Control panel
  • MyVallox Home/Cloud user interface
  • CO2, %RH, and VOC control
  • Remote monitoring control (voltage message, Modbus)
Accessories
  • MyVallox carbon dioxide sensor (optional)
  • MyVallox humidity sensor (optional)
  • MyVallox VOC sensor
  • Insulated attic floor penetration plate
  • Ceiling mounting plate Vallox 101 MV
  • MyVallox KNX bus adapter
Annual efficiency classification of heat recovery from extract air A+