Fireplace profile

Tip

Use the Right arrow button to view the Fireplace profile settings.

To make the Fireplace profile settings:

  1. The Fireplace profile display of the setup wizard opens:

  2. Use the Plus and Minus buttons to set the profile timer duration in hours and minutes. This value indicates the duration of enhanced ventilation when the Fireplace profile is activated.

  3. Select Right arrow.

  4. A display for setting the profile supply air fan speed opens.

  5. Use the Plus and Minus buttons to set the supply air fan speed of the Fireplace profile as a percentage of the maximum output ratio.

    Note

    It is recommended that a higher supply air fan speed be used in the Fireplace mode to create overpressure in the ventilation zone. Reducing the extract air fan speed is not recommended.

  6. Select Right arrow.

  7. A display for setting the profile extract air fan speed opens.

  8. Use the Plus and Minus buttons to set the extract fan speed of the Fireplace profile as a percentage of the maximum output ratio.

  9. Select Right arrow.

    A display for setting the profile timer opens.

  10. Use the Plus and Minus buttons to select whether the profile timer function is used or not. The options are:

    • On — When the timer is on, the Fireplace profile is used only for the period specified in the timer.

    • Off — When the timer is off, the Fireplace profile is used until you (or the week clock) change the profile.

  11. Select OK:

    The Fireplace profile settings are now complete.