Viewing the Away profile information

To view the Away profile settings:

  1. Select Control panel.

  2. Use the mouse to select the Away profile in the Profiles area.

  3. The basic information of the selected profile is displayed:

    This area shows the following information:

    • Fan speed — Indicates the fan speed. If the automatic fan speed boost is turned on, the set value is shown in brackets first followed by the actual fan speed.

    • Supply air — Indicates the temperature of the air blown into the apartment and its set value (in brackets), if the supply air is warmer than the set value.

    • Humidity — Indicates the highest relative humidity of air measured by the sensors.

    • Carbon dioxide — Indicates the highest carbon dioxide level measured by the sensors.

    • Cell status — Indicates the status of the ventilation unit heat recovery cell. The status options are:

      • Heating — The heat recovery cell heats the air streaming in from outdoors with extraction air.

      • Cooling — The heat recovery cell cools the air streaming in from outdoors with extraction air when the temperature of the air that is extracted from the apartment is two degrees lower than the outdoor temperature.

      • Bypass — The inflowing air bypasses the heat recovery cell.

      • Defrosting — The heat recovery cell is being defrosted.

  4. The profile display in the Information area contains more information.

    See also the section called “Symbols for ventilation profiles”.