Symbols for ventilation profiles

The figure below shows an example of the profile display:

The following symbols are used on the profile displays:

Table 75. Profile symbols

SymbolDescription

Either the At home, Away or Boost profile is in use. The week clock is turned off.

Either the At home, Away or Boost profile is in use. The week clock is on.

The Fireplace profile is in use The week clock might be turned on.

These symbols indicate the currently active profile. The smallest fan icon indicates that the Away profile is in use, and the largest fan icon indicates that the Boost profile is being used.

Droplet symbols indicate the relative humidity of air. The symbols are:

  • One drop — The humidity sensor has been successfully installed and the relative humidity of air is normal.

  • Two drops — The relative humidity of air is slightly higher than normal. The fan speed will be automatically increased if automatic adjustment is allowed.

  • Three drops — The relative humidity of air is significantly higher than normal. The fan speed will be automatically increased if automatic adjustment is allowed.

These symbols indicate the carbon dioxide level in the air. The colour codes are:

  • Green — The carbon dioxide sensor has been installed and the carbon dioxide level is normal.

  • Orange — The carbon dioxide level is slightly higher than normal. The fan speed will be automatically increased if automatic adjustment is allowed.

  • Red — The carbon dioxide level is significantly higher than normal. The fan speed will be automatically increased if automatic adjustment is allowed.