Defrost settings

This section describes making the following defrost-related settings:

To make the aforementioned settings:

  1. Select Expert settings.

  2. Defrost settings are described in the Defrost settings area.

  3. Select one of the following defrosting methods from the Defrosting method drop down menu.

    • Bypass — If the Bypass is selected as the defrosting method, the heat recovery cell will be bypassed on the supply air side. This does not change the ratio between the supply and extract air flows. In some cases this prevents the generation of potentially harmful underpressure in the apartment.

      In the Bypass state, the electric resistor heats the cool air streaming in from outside to the set temperature for the duration of the defrosting cycle. If the set temperature is too relative to the outdoor temperature, the unit reduces the supply and extract air flows to achieve the set supply air temperature.

    • Supply fan stop — If Supply fan stop is set as the defrosting method, the supply air fan will be stopped for the entire defrosting cycle. A momentary underpressure is created in the apartment.

    Important

    The parametres need not be changed in normal living conditions. Exceptional conditions include high moisture loads caused by e.g. pool premises, or the accumulation of a problematic amount of ice in the exhaust air channel.

    The defrosting method is now set.

  4. Set the relative humidity of air by moving the blue Humidity slider to the desired value.

    The relative humidity of air value can be set between -50 % – +50 % RH.

  5. The relative humidity of indoor air is now set.

  6. Set the outdoor air temperature by moving the blue Outdoor air slider to the desired value.

    You can set a value between 0–100%. The factory setting depends on the type of the ventilation unit.

  7. The outdoor air temperature is now set.