Mounting on a base

MyVallox 119 CFi must always be installed on a base on the floor, on a wall mounting plate on the wall, and on a ceiling mounting plate on the ceiling.

Note:
A space of at least 555 mm must be reserved in front of the unit for maintenance purposes.
Note:
Install the ventilation unit in a place where the temperature does not drop below +10°C.

The base is optional. Adjust the base with adjusting legs to level it. Remove the rubber plugs (4 pcs) at the bottom of the unit. Place the unit on top of the base so that the bars of the base fit in the holes at the bottom of the unit. Mount the ventilation unit on the base, as shown in the figure. Make sure that the unit is horizontally level after mounting.

AThread bar M8 x 35, shorter thread upward.
BThe length of the adjusting screw is 37 mm.