Viewing the Fireplace mode information
To view the basic settings of the Fireplace mode:
- Select Operation menu.
-
Click on the Fireplace mode in the Ventilation modes area to select it.
-
The basic settings of the selected mode will be displayed:
This area shows the following information:
- Supply fan — Indicates the supply air fan speed as a percentage of the maximum. The volume in litres per minute is given in brackets.
- Extract fan — Indicates the extract air fan speed as a percentage of the maximum. The volume in litres per minute is given in brackets.
- Duration — Indicates the duration of enhanced ventilation when the said mode is activated. The value is shown in hours and minutes.
-
The ventilation mode display in the Information area contains more information.
- Fan speed — Indicates the fan speed. If the automatic fan speed boost is turned on, the set value is shown in brackets first followed by the actual fan speed.
- HR cell status — Indicates the status of the ventilation unit heat recovery cell. Possible statuses are:
- Heat recovery — The heat recovery cell heats the air flowing in from outdoors with extract air.
- Cool recovery — The heat recovery cell cools the air flowing in from outdoors with extract air when the temperature of the air that is extracted from the apartment is two degrees lower than the outdoor temperature.
- HR cell bypass — The inflowing air bypasses the heat recovery cell.
- Defrosting the HR cell — The inflowing air bypasses the heat recovery cell.
-
Relative humidity of the air — Indicates the highest relative humidity of air measured by the sensors.
-
Carbon dioxide level — Indicates the highest carbon dioxide level measured by the sensors.