Installation of the Vallox Captura Cooker hood

The Vallox Captura cooker hood is installed on the bottom of Vallox 51K MV.

  1. Remove the plug from the feedthrough seal of the condensing water tube of the cooker hood.
  2. Lift the cooker hood and fit the hooks at the rear of the cooker hood into the holes at the bottom of the ventilation unit. Push in place.
  3. Ensure that the feedthrough seal of the condensing water tube sits firmly around the tube.
  4. Lift the front of the cooker hood to fit the mountings into the penetrations in the bottom of the ventilation unit.
  5. Fasten the M5 hexagon screws (2) through the mountings.
  6. Lead the power cord and the control cable up along the cable channel. Wind approx. half a metre of the cables behind the cooker hood so that it can be removed for maintenance purposes where required.
  7. Move the metal cover backwards so that it covers the opening between the cooker hood and the wall.
    Important:

    The minimum clearance between the bottom edge of the cooker hood and an electric stove is 426 mm.